14-6 Measuring Operating Current
Device Characterization - DC Tests
Execute
7 Click the
exec
button.
N O T E
Most data sheets specify such tests to be done with outputs open. For
devices with IO pins, this may require a special vector set that ensures
the driver is tristated during the time the measurement is made.
The sequencer is started from the label defined in the Data Manager
window. After the delay time has elapsed, the current flowing through
the DPS pins is measured.
After the measurement, a check is done to make sure the sequencer is
still running. If not, an error is returned instead of the measurement
results.
Afterwards the sequencer is stopped. If needed, the pins are returned
to normal connected state (load is reconnected).