Standard Test Functions
330
• The third waveform enables tristate on for edge 1 and compare to
intermediate for edge 2. This is the waveform used by the measured
pin in the fourth cycle of the functional test.
The continuity set also defines a special vector setup comprising four
cycles for each pin. Each pin is the measured pin for four cycles.
The commutation voltage used by the programmable load during the
measurement is always set according to the pass voltage that you have
defined. The value is always 1V above or below V
Figure
209, and has a range of - 2V to +6V.
In
Figure
polarity of the test current. If you've set the both polarities option and
the first test fails, the result for the whole test is failed. If the first test
passes, the test is repeated with the commutation voltage as well as the
pass min/max voltages set to the opposite polarity. If this reverse
measurement fails, the result for the whole test is failed, otherwise it is
passed. The end state for the test is disconnected.
Setting up the test
Select contin.cont from the Data Manager
Continuity Test Window is displayed as shown below.
Figure 209
Continuity Test Window, Programmable Load Selected
Select the Test Options required and then:
Agilent 93000 SOC Series User Training Part 1, October 2004
209, the polarity of the commutation voltage is set by the
11-4 The Continuity Test Function
as shown in
pass_max