Defining the Levels
Level Equation Set
154
The first four modules (Level Sets, DPS module, Spec module and
Equation module) are comprised in a Level Equation Set.
Figure 83
illustrates the structure of the level setup.
Level Equation Editor
LEVEL EQN SET n
. . .
LEVEL EQN SET 2
LEVEL EQN SET 1
Spec
SPECS
declaration
<spec 1>
<spec 2>
. . .
<spec k>
EQUATIONS
DPSPINS
LEVELSET 1
. . .
LEVELSET k
Figure 83
Sets Involved in the Level Setup
You can define a maximum of
• 99 equation sets
• 99 spec sets
• 256 level sets across all equation sets.
The level setup information is stored in a level file. The level file resides
in the level sub-directory of the device directory.
The specific values of the level resources are calculated from the infor-
mation of the
• EQUATION SETS defined in the Equation Editor (see
Agilent 93000 SOC Series User Training Part 1, October 2004
8-3 Overview of the Level Setup
Level Spec Tool
Spec Sets defined for LEVEL EQN SET 1
LEVEL SPEC SET 11
Select a Spec Set
LEVEL SPEC SET 12
. .
.
LEVEL SPEC SET 1m
A spec set assigns
values to the specs
declared in the LEVEL
EQN SET
<spec 1> = 4.5V
<spec 2> = 0.5V
. . .
<spec k> = 5V
<spec 1> = 4.8V
<spec 2> = 0.2V
. . .
<spec k> = 5.5V
<spec 1> = 2.5V
<spec 2> = 2.0V
. . .
<spec k> = 4.5V
Figure
84),