Agilent Technologies 93000 SOC Series Training Manual page 442

User training part 1
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

Shmoo Tool
442
6 Enter the parameters to be varied.
The parameters for both axes are defined in the same way as for the
Global Search function.
Instead of specifying the stepwidth, you may also specify the
number of steps by entering #<number> in the
an integer between 1 and 100).
You can also specify a test file to be executed with normal
timing/voltage settings prior to setting parameters for each point in the
Shmoo. For example, you could use this to restore some condition in
the device which might be altered at a fail point in the Shmoo (very
useful for programmable logic or memories).
Since this test is done for each point in the Shmoo, the test time could
increase significantly.
Agilent 93000 SOC Series User Training Part 1, October 2004
16-2 Sweep Test Function Overview
row (number is
STEP