Advanced Testflow Control
Open System Flags window
518
Figure 316
Global OOC Window
2 Enter the OOC sample size.
The global sample size serves as a multiplier for the other entries.
The first analysis is made after a multiple of this sample size. All
subsequent analysis is made upon the last multiples of this size. The
global sample size also affects the rules for the single bins.
3 Enter the rules for OOC Warning and OOC Pause Test.
These are similar to the OOC rules for each single bin. The OOC for
single bins are only needed if there is more than one good bin.
The rules allow decisions to be made based on the overall good
yield.
N O TE
The "on_pause" section of your application model determines the
actions taken if an OOC pause test occurs.
How to Access the System Flags
1 Either
– Select
or
click the
Agilent 93000 SOC Series User Training Part 1, October 2004
Select - System
Flags.
button.
18-5 Information and Flags