Sensor Module External; Sensor Module Sme 20/25; Sensor Module External 120/125 - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

9.5.3.2

Sensor Module External

A Sensor Module External (SME) is required if the sensor interface is to be installed close to
the motor sensor outside a control cabinet. The SME has an IP67 degree of protection.
9.5.3.3

Sensor Module SME 20/25

The SME20 and SME25 evaluate encoder and sensor data. The calculated values are
transferred to the Control Unit via DRIVE-CLiQ. SME20 and SME25 differ regarding the
encoder interface.
A temperature sensor cannot be connected to the SME25 to sense the motor temperature.
Instead, use an SME125.
9.5.3.4

Sensor Module External 120/125

A Sensor Module External 120 (SME120) or Sensor Module External 125 (SME125) is
required for the following application conditions:
● The sensor interface is installed close to the motor outside a control cabinet
● Several motor temperature channels are required
● The motor temperature sensors do not have safe protective separation
● Safe protective separation is not possible.
SME12x has an IP67 degree of protection. SME12x are particularly suitable for linear and
torque motor applications.
If r0458[0...2].8 = 1, up to three temperature sensors can be connected at terminal block
X200. Each sensor is assigned to a temperature channel.
The SME12x evaluates the data of the temperature sensors and makes the calculated
values available via DRIVE-CLiQ for further processing.
Table 9- 4
Terminal Function
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Assignment of terminal strip X200 for the temperature sensors
Channel
1
-Temp
2
2
+Temp
3
+Temp
3
4
-Temp
5
+Temp
4
6
-Temp
Parameter
Temperature sensor type
p4601[0]
KTY84/PTC/bimetallic NC contact
Linear and torque motors: KTY84
p4602[0]
KTY84/PTC/bimetallic NC contact
Linear and torque motors: PTC – triplet 1 or bimetal
NC contact
p4603[0]
KTY84/PTC/bimetallic NC contact
Linear and torque motors: PTC – triplet 1 or bimetal
NC contact
Monitoring and protective functions
9.5 Thermal motor protection
559