Siemens SINAMICS S120 Function Manual page 459

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

DDS p0186
p0187
(MDS)
(encoder1)
8
0
EDS0
9
4
EDS6
The referencing bit (r2684.11) is reset for a DDS changeover. If, in the new DDS, the EDS already has an adjusted
1)
encoder, then the referencing bit is set again.
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
p0188
p0189
(encoder2)
(encoder3)
EDS1
EDS2
EDS0
EDS2
Encoder
Mechanical
for
conditions
position
p2504/
control
p2505/
p2502
p2506/
p2503
encoder_1 xxx
encoder_1 www
Function modules
8.7 Closed-loop position control
Position
Changeover response
tracking
Load gear
Deactivate
Pulse inhibit/operation:
d
Referencing bit is reset.
Position tracking for EDS0
is no longer calculated
and, as a consequence,
the actual position value
also changes (the offset
correction of the position
tracking is canceled).
When switching back to
DDS0, the position
tracking for EDS0 is newly
initiated and the
referencing bit is reset.
only makes sense to
switch back to DDS0
without a new adjustment
in DDS0 if the user did not
make a new adjustment in
DDS8 and the permissible
tolerance window (p2722)
was not exited.
Activated
Pulse inhibit/operation:
Position tracking for EDS6
is newly initiated and the
referencing bit is reset.
When switching back to
DDS0, the same applies
to EDS0.
1)
It
1)
1)
459