Test Scope For Specific Measures - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

10.10.1.3

Test scope for specific measures

Scope of partial acceptance tests for specific measures
The measures and points specified in the table refer to the information provided in Section
Content of the partial acceptance test (Page 621).
Table 10- 7
Scope of partial acceptance tests for specific measures
Measure
A) Documentation
Replacement of
Yes, Points 1 and
the Control Unit
2
/ power unit
hardware
Replacement of
Yes, Points 1 and
the Power
2
Module or Safe
Brake Relay
Firmware -
Yes, only Point 2
upgrade (CU /
power unit /
Sensor
Modules)
Change to a
Yes, Points 4 and
single
5.
parameter of a
safety function
(e.g. SLS limit)
Transfer of
Yes
project data to
other machines
(series
commissioning)
New firmware
Yes, only Point 2
version for
SIMOTION D
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
B) Functional testing
C) Functional testing
of safety functions
of the forced dormant
error detection
No
Yes, only Point 1
Yes, Points 1 or 2
Yes, only Point 1
and 3
Yes, if new safety
Yes
functions are to be
used
Yes, test the
No
appropriate function
Yes, but only testing
Yes
of the selection of the
safety functions
Yes, if new safety
Yes
functions are to be
used
Safety Integrated basic functions
10.10 Acceptance test and certificate
D) Functional
testing of actual
value acquisition
Yes, only Point 1
Yes, only Point 1
Yes, only Point 1
Yes
Yes
Yes, only Point 1
E) Conclusion
of the report
Yes
Yes
Yes
Yes
Yes
Yes
623