13.5.4

Analog outputs

Signal processing using the analog outputs is shown in the function diagrams listed below.
Properties
● Adjustable absolute-value generation
● Inversion via binector input
● Adjustable smoothing
● Adjustable transfer characteristic
● Output signal can be displayed via visualization parameter
Note
Parameters p4077 to p4080 of the scaling do not limit the voltage values / current values (for
TM31, the output can be used as current output).
Function diagrams (see SINAMICS S120/S150 List Manual)
• 9106
• 9572
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Terminal Board 30 (TB30) - Analog outputs (AO 0 ... AO 1)
Terminal Module 31 (TM31) - Analog outputs (AO 0 ... AO 1)
Basic information about the drive system
13.5 Inputs/outputs