X21 EP terminals/temperature sensor motor module

Table 5-3
X21 EP terminal/temperature sensor
Terminal
1
2
3
4
Type: Spring-loaded terminal 1 (Page 177)
Accuracy of the temperature measurement (temperature sensor, including evaluation):
1)
- Pt1000: ±5 °C (Pt1000 tolerance Class B acc. to DIN EN 60751)
- PTC: ±5 °C
- KTY: ±7 °C
EP terminal
The filter times to debounce terminals X21.3 and X21.4 are set using parameters. You can find
additional information in the SINAMICS S120/S150 List Manual. Additional parameter settings
are also required in order to prevent discrepancy errors when performing bit pattern tests (light/
dark tests). For comprehensive information, see the SINAMICS S120 Safety Integrated Function
Manual, Chapter "Controlling the safety functions".
Electric shock when connecting unsuitable voltages
Touching parts and components that are at excessively high voltages can result in death or
severe injury.
• Only connect safety extra-low voltages (PELV/SELV) at terminals "EP +24 V" and "EP M1".
Temperature sensor
Electric shock when the motor temperature sensor insulation fails
When connecting temperature sensors which are not isolated from the motor power circuit in
line with safe electrical separation, arcing to the signal electronics may occur.
• Use temperature sensors whose temperature sensor has safe electrical separation.
• If safe electrical separation cannot be guaranteed (for linear motors or third-party motors,
High Frequency Drive
System Manual, 10/2020, 6SL3097-5AH10-0BP0
Function
+ Temp
- Temp
EP +24 V (enable pulses)
EP M1 (Enable Pulses)
WARNING
WARNING
for example), use the Terminal Module TM120.
Technical data
Temperature sensors
1)
: Pt1000 / PTC / KTY84-130 / bimet‐
allic switch with NC contact
Supply voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption at 24 V: 10 mA
Isolated input
The pulse inhibit function is only available when Safety
Integrated Basic Functions are enabled.
High Frequency Modules
5.3 HF Motor Module
45