Siemens SINAMICS S120 Function Manual page 74

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Extended setpoint channel
3.9 Ramp-function generator
Properties of the basic ramp-function generator
Figure 3-8
● Ramp-up time T
● Ramp-down time T
● OFF3 ramp-down:
– OFF3 ramp-down time p1135[0...n]
● Set ramp-function generator:
● Freezing of the ramp-function generator using p1141 (not in jog mode r0046.31 = 1)
74
Ramp-up and ramp-down with the basic ramp-function generator
p1120[0...n]
up
p1121[0...n]
dn
– Setting value ramp-function generator p1144[0...n]
– Signal, set ramp-function generator p1143[0...n]
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents