Preconditions for PN Gate

Hardware
● SINAMICS CU320-2 PN with firmware version as of 4.5
● Communication Board Ethernet 20 (CBE20)
● Short Ethernet cable to connect CBE20 and CU320-2 PN (X150)
Recommendation: Ethernet cable with the order number: 6SL3060-4AB00-0AA0
● Control hardware with standard Ethernet interface (100 Mbit/s or higher),
for example, the SIMATIC Box IPC 427C.
Note
The Gate PC must guarantee the short latency times required for operating the PN Gate.
Influencing variables are the CPU performance, mainboard hardware (Ethernet chipset and
its connection), and the BIOS and the software components involved (operating system
components such as memory mapping, Ethernet driver, interrupt link, configuration).
Software
● STARTER as of V4.3
or
● Drive ES as of V5.5
or
● SIMATIC STEP 7 as of V5.5 SP2
Development kit for the development and configuration:
● SINAMICS PN Gate DevKit (MLFB 6SL3071-0CA00-0XA0)
Licenses
● The PN Gate CU requires a runtime license with the MLFB 6SL3074-0AA03-0AA0 or the
Z option G01 for CFC.
PROFINET version
● SINAMICS PN Gate V2 is compatible with PROFINET V2.2