Function modules
8.2 Extended monitoring functions
Commissioning
This function module can be activated via the commissioning wizard.
You can check the current configuration in parameter r0108.17.
Function diagrams (see SINAMICS S120/S150 List Manual)
• 8010
• 8011
• 8013
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Load monitoring
• p2181[0...n]
• p2182[0...n]
• p2183[0...n]
• p2184[0...n]
• p2185[0...n]
...
• p2190[0...n]
• p2192[0...n]
Speed setpoint monitoring
• p2150[0...n]
• p2151[0...n]
• p2161[0...n]
• r2198.4
• r2198.5
434
Signals and monitoring functions - Speed messages 1
Signals and monitoring functions - Speed messages 2
Signals and monitoring functions - Load monitoring (r0108.17 = 1)
Load monitoring, response
Load monitoring, speed threshold 1
Load monitoring, speed threshold 2
Load monitoring, speed threshold 3
Load torque monitoring torque threshold 1, upper
Load torque monitoring torque threshold 3, lower
Load monitoring, delay time
Hysteresis speed 3
CI: Speed setpoint for messages
Speed threshold 3
CO/BO: Status word, monitoring 2, |n_set| ≤ p2161
CO/BO: Status word, monitoring 2, n_set < 0