Basic functions
7.23 Terminal Module 41
Example of a pulse number step-up ratio
The leading encoder emits 12 pulses and a zero mark per revolution. However, the
application requires 32 pulses per revolution. By setting p4408 and p4418, the required 32
pulses a revolution are available at X520 of the TM41.
Figure 7-20
Step-up ratio of the encoder pulse number