Safe Stop 1 (SS1, time controlled)

10.5.1

SS1 with OFF3

The "Safe Stop 1" (SS1) function allows the drive to be stopped in accordance with
EN 60204-1, Stop Category 1. The drive decelerates with the OFF3 ramp (p1135) once
"Safe Stop 1" is selected and switches to "Safe Torque Off" once the delay time set in p9652
has elapsed.
Note
Selection via terminals
The selection of the "Safe Stop 1" (time-controlled) function via terminals is parameterized
by setting a delay > 0 in p9652. In this case, the STO function can no longer be selected
directly via terminals, i.e. either STO or SS1 can be selected via terminals.
If the "Safe Stop 1" (time-controlled) function has been selected by parameterizing a delay
time in p9652, STO can no longer be selected directly via terminals.