Activation Of The "Extended Setpoint Channel" Function Module In Servo Control - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Extended setpoint channel

3.1 Activation of the "extended setpoint channel" function module in servo control

3.1
Activation of the "extended setpoint channel" function module in
servo control
In servo control, the "extended setpoint channel" function module can be activated via the
commissioning wizard or the drive configuration (configure DDS).
You can check the current configuration in parameter r0108.8. Once you have set the
configuration, you have to download it to the Control Unit where it is stored in a non-volatile
memory (see the SINAMICS S120 Commissioning Manual).
Note
When the "extended setpoint channel" function module for servo control is activated, under
certain circumstances, the number of drives in the multi-axis group that can be controlled
from a Control Unit is reduced.