Siemens SINAMICS S120 Function Manual page 829

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Display
P
C
Below, 6 digit
Information on the keys
Table 13- 8
Keys
Key
Name
ON
OFF
Functions
Parameter
Raise
Lower
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Meaning
Is lit (bright) if, for a parameter, the value only becomes effective after pressing the P key.
Is light (bright) if at least one parameter was changed and the calculation for consistent data
management has still not been initiated.
Displays, e.g. parameters, indices, faults and alarms.
Meaning
Powering up the drives for which the command "ON/OFF1" should come from the BOP.
Binector output r0019.0 is set using this key.
Powering down the drives for which the commands "ON/OFF1", "OFF2" or "OFF3" should come
from the BOP.
The binector outputs r0019.0, .1 and .2 are simultaneously reset when this key is pressed. After
the key has been released, binector outputs r0019.1 and .2 are again set to a "1" signal.
Note:
The effectiveness of these keys can be defined by appropriately parameterizing the BICO (e.g.
using these keys it is possible to simultaneously control all of the existing drives).
The significance of this key depends on the actual display.
Note:
The effectiveness of this key to acknowledge faults can be defined using the appropriate BiCo
parameterization.
The significance of this key depends on the actual display.
If this key is pressed for 3 s, the "Copy RAM to ROM" function is executed. The "S" displayed on
the BOP disappears.
The significance of these keys is dependent on the actual display and is used to increase or
decrease values.
13.7 Parameterizing using the BOP20 (Basic Operator Panel 20)
Basic information about the drive system
829