Siemens SINAMICS S120 Function Manual page 725

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Module
Subslot 1
MAP
TM150
MAP
TM41
MAP
Control Unit
MAP
TM15/TM17
Not supported.
The telegrams in subslots 2, 3 and 4 can be freely configured, i.e. they can also remain empty.
Configuration
Configuring the three versions is only briefly sketched out in the following:
Compact modules (as before):
1. Insert a "DO SERVO/VECTOR/..." module.
2. Assign the I/O addresses.
Subslot configuring without new functionality:
1. Insert a module "DO with telegram xyz".
2. Insert a submodule "PZD telegram xyz".
3. Assign the I/O addresses.
Subslot configuring with optional PROFIsafe and PZD extension:
1. Insert a "DO SERVO/VECTOR/..." module.
2. Insert the optional submodule "PROFIsafe telegram 30".
3. Insert a submodule "PZD telegram xyz".
4. Insert the optional submodule "PZD extension".
5. Assign the I/O addresses for the module and the submodules.
You will find a detailed description for processing a GSDML file in HW Config in the SIMATIC
documentation.
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Subslot 2
Subslot 3
PROFIsafe
PZD telegram
Reserved
Telegrams: no
free PZD-4/4
Reserved
Telegrams: 3
free PZD-4/4, 16/16
Reserved
Telegrams: 390, 391, 392,
393, 394, 395
free PZD-4/4
11.3 Communication via PROFINET IO
Subslot 4
PZD extension
Reserved
Reserved
Reserved
Communication
Max. number
of PZD
7/7
20/28
5/21
725