Overview Of Important Parameters - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.19.15

Overview of important parameters

Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p0404[0...n]
• p0405[0...n]
• p0408[0...n]
• p0430[0...n]
• p0437[0...n]
• p0438[0...n]
• r0452[0...n]
• r0458[0...n]
• r0459[0...n]
• p4680[0...n]
• p4681[0...n]
• p4682[0...n]
• p4683[0...n]
• p4684[0...n]
• p4686[0...n]
• r4688[0...n]
• r4689[0...n]
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Encoder configuration active
Square-wave encoder track A/B / square-wave encoder A/B
Rotary encoder pulse No.
Sensor Module configuration
Sensor Module extended configuration
Square-wave encoder filter time
Square-wave encoder filter time display
Sensor Module properties
Sensor Module extended properties
Zero mark monitoring tolerance permissible
Zero mark monitoring tolerance window limit 1 positive
Zero mark monitoring tolerance window limit 1 negative
Zero mark monitoring tolerance window alarm threshold positive
Zero mark monitoring tolerance window alarm threshold negative
Zero mark, minimum length
Zero mark monitoring, number of differential pulses
Square-wave encoder diagnostics
Basic functions
7.19 Tolerant encoder monitoring
349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents