Basic information about the drive system
13.2 Data sets
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p0120
• p0130
• p0139
• p0140
• p0170
• p0180
• p0186 [0...n]
• p0187[0...n]
• p0188[0...n]
• p0189[0...n]
• p0809[0...2]
• p0810
• p0811
• p0819[0...2]
• p0820[0...n]
• p0821[0...n]
• p0822[0...n]
• p0823[0...n]
• p0824[0...n]
804
Power Module data sets (PDS) number
Motor data sets (MDS) number
Copy motor data set (MDS)
Encoder data sets (EDS) number
Command data set (CDS) number
Drive data set (DDS) number
Motor data sets (MDS) number
Encoder 1 encoder data set number
Encoder 2 encoder data set number
Encoder 3 encoder data set number
Copy Command Data Set CDS
BI: Command data set selection CDS bit 0
BI: Command data set selection CDS bit 1
Copy drive data set DDS
BI: Drive data set selection DDS, bit 0
BI: Drive data set selection DDS, bit 1
BI: Drive data set selection DDS, bit 2
BI: Drive data set selection DDS, bit 3
BI: Drive data set selection DDS, bit 4
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Drive functions