Table 11- 23 Receive data for Control Unit 2
From the sender
Transfer
Tel. word
from
p8871[x]
p2051[0]
0
p2061[1]
1
2
p2061[3]
3
4
p2051[5]
5
p2051[4]
6
p2061[5]
7
8
p2061[6]
9
10
p2051[7]
11
p2051[8]
12
p2061[9]
13
14
-
15
Tel. word = telegram word
Note
For double words, two PZD must be read in succession. Read a 32-bit setpoint that is at
PZD 2+PZD 3 of the telegram from node 2, and map this to PZD 2+PZD 3 of node 1:
p8872[1] = 2, p8870[1] = 2, p8872[2] = 2, p8870[2] = 3
Activation
To activate SINAMICS Link connections, perform a POWER ON for all nodes. The
assignments of p2051[x]/2061[2x] and the links of the read parameters r2050[x]/2060[2x]
can be changed without a POWER ON.
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Address
Receive buffer
p8872[x]
p8870[x]
1
PZD 1
1
PZD 2
1
PZD 3
1
PZD 4
1
PZD 5
1
PZD 6
1
PZD 7
1
PZD 8
1
PZD 9
1
PZD 10
1
PZD 11
1
PZD 12
1
PZD 13
1
PZD 14
1
PZD 15
0
PZD 16
11.4 Communication via SINAMICS Link
Receiver
Data transferred in
Parameter Contents
r2050[x]
r2060[x]
0
-
r0899
-
1
r0061[0]
-
r0061[0]
-
3
r0080
-
5
-
r2131
6
-
r0899
-
7
r0061[0]
-
-
9
r0080
-
11
-
r2131
12
-
2138
-
13
r0046
-
15
-
0
Communication
ZSW1
Actual speed value part 1
Actual speed value part 2
Actual torque value part 1
Actual torque value part 2
Actual fault code
ZSW1
Actual speed value part 1
Actual speed value part 2
Actual torque value part 1
Actual torque value part 2
Actual fault code
Control word, faults/alarms
Missing enables part 1
Missing enables part 2
Empty