8. Click "Specify".
9. In the "New password" field, enter the password (1 to 30 characters). Pay attention to
10.Enter it again in the "Confirm password" field and click "OK" to confirm the entry.
11.If, despite active know-how protection, you permit diagnostic functions, activate the "Allow
12.The "Copy RAM to ROM" option is active by default and ensures that the know-how
13.Click "OK".
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
The "Know-how Protection for Drive Unit - Specify Password" dialog box opens.
Figure 13-29 Setting the password
upper- and lower-case.
The dialog box is closed and the password is shown in encrypted form in the "Activate
Know-how Protection for Drive Object" dialog box.
diagnostic functions (trace and measuring functions)" option with a mouse click.
This allows the trace function, the measuring function and the function generator to be
used despite know-how protection.
protection is permanently stored in the Control Unit. If you want to use the know-how
protection temporarily, deactivate this option.
Know-how protection is now activated. If larger data volumes are being encrypted, a
progress display informs that the encryption or the activation of the know-how protection
is still running.
The text "Know-how protected" then appears instead of the content in all protected
parameters of the expert list.
Note
For published DCC parameters, the entry "--" appears in the expert list instead of the text
"Know-how protected".
Basic information about the drive system
13.15 Write and know-how protection
901