10.10.1.2

Content of the partial acceptance test

A) Documentation
Documentation of the machine and safety functions
1. Extending/changing the hardware data
2. Extending/changing the software data (specify version)
3. Extending/changing the configuration diagram
4. Extending/changing the function table:
5. Extending/changing the SI functions per drive
6. Extending/changing the specifications of the safety equipment
B) Functional testing of safety functions
Detailed function test and evaluation of SI functions used. For some functions this contains
trace recordings of individual parameters. The procedure is described in detail in section
Acceptance tests (Page 628).
The function test can be left out if no parameters of the individual safety functions have been
changed. In the case that only parameters of individual functions have been changed, only
these functions need to be tested anew.
When testing the functions STO, SS1 and SBC, you do not have to make any trace
recording.
C) Functional testing of the forced dormant error detection
Testing the forced dormant error detection of the safety functions on each drive (for each
control type).
● Testing the forced dormant error detection of the safety function on the drive
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
– Active monitoring functions depending on the operating mode and the protective door
– Other sensors with protective functions
– The table is part or is the result of the configuring work
– If you are using Basic Functions, you need to activate and then deactivate STO once
again.
– If you are using Extended Functions, you need to carry out a test stop / forced
dormant error detection.
Safety Integrated basic functions