Jog Operation: Fjog/Rjog - YASKAWA V1000 Series Installation & Start-Up Manual

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

4.5 Test Run
Parameter
No.
Name
Selects which parameters are accessible via the digital
operator.
Access
0: Operation only (access to A1 and U group parameters
A1-01
Level
only)
Selection
1: User Parameters (access to a set of parameters selected
by the user)
2: Advanced Access Level (access to all parameters)
Parameters selected by the user are stored to the User
Parameter menu. This includes recently viewed parameters
or parameters specifically selected for quick access.
A2-01
Preferred
If parameter A2-33 is set to 1, recently viewed parameters
to
Parameters
will be listed between A2-17 and A2-32. Parameters A2-01
A2-32
1 to 32
through A2-16 must be manually selected by the user.
If A2-33 is set to 0, then recently viewed parameters will
not be saved to the User Parameter group. The entire A2
parameter group is now available for manual programming.
0: Parameters A2-01 through A2-32 are reserved for the
Preferred
user to create a list of User Parameters.
Parameter
A2-33
1: Save history of recently viewed parameters. Recently
Automatic
edited parameters will be saved to A2-17 through A2-32 for
Selection
quick access.
Password Settings: A1-04, A1-05
The user can set a password to the drive to restrict access. The password is selected
via parameter A1-05. The selected password must be entered in parameter A1-04
to unlock parameter access (i.e. parameter setting A1-04 must match the value
programmed into A1-05). The following parameters cannot be viewed or edited
until the value programmed into A1-04 correctly matches the value as programmed
in parameter A1-05: A1-01, A1-02, A1-03, A1-06 and A2-01 through A2-33.
Note: Parameter A1-05 is hidden from view. To display A1-05, access parameter A1-04
and simultaneously depress the

Jog Operation: FJOG/RJOG

Implement Forward and Reverse Jog functions using the multi-function input
terminals (S1 to S7). Separate frequency settings for forward jog (FJOG) and
reverse jog (RJOG) cannot be set. The jog frequency reference for both forward
and reverse jog commands is set in parameter d1-17.
174
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
key and the
Setting
Default
Range
0 to 2
b1-01 to
o2-08
0,1
key.
Page
2
333
334
1
334

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents