B.2 Parameter Table
No.
Name
A1-04 Password 1
A1-05 Password 2
Application
A1-06
Preset
DriveWorksEZ
A1-07
Function
<22>
Selection
A2-01
to
User Parameters,
A2-32
1 to 32
<22>
User Parameter
A2-33
Automatic
Selection
<4> Default setting value is dependent on parameter A1-06. This setting value is 0 when A1-06 = 0, and 1 when A1-
06 does not = 0.
<16> Default setting value is dependent on parameter A1-06, Application Selection.
<22> Parameter can be changed during run.
334
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
When the value set into A1-04 does not match the
value set into A1-05, parameters A1-01 thru A1-
03, A1-06, and A2-01 thru A2-32 cannot be
changed.
Sets parameters that are commonly used in certain
applications to A2-01 through A2-16 for easier
access.
0: General-purpose (A2 parameters are not
affected)
1: Water supply pump
2: Conveyor
3: Exhaust fan
4: HVAC fan
5: Air compressor
6: Hoist
7: Crane (hoist, traverse)
0: Disabled
1: Enabled
2: Multi-function input (enabled when H1-xx = 9F)
A2: User Parameters
Use A2 parameters to program the drive.
Parameters that were recently edited are listed here.
The user can also select parameters to appear here
for quick access.
Parameters will be stored here for quick access
when A1-01 = 1.
0: Parameters A2-01 through A2-32 are reserved
for the user to create a list of User Parameters.
1: Save history of recently viewed parameters.
Recently edited parameters will be saved to A2-17
through A2-32 for quick access.
Control
Mode
Range Def.
O
V/
P
L
f
M
V
0 to
0
A A A 104
9999
0 to
0
A A A 105
9999
This parameter is hidden from
view. To access A1-05, first
display A1-04. Then press the
STOP key while holding down
the up arrow key. Parameter
A1-05 will appear.
0 to 7
0
A A A 127
0 to 2
0
A A A
--
b1-01 to
A A A
<16>
o2-08
1
0,1
A A A 126
<4>
Addr.
Pg.
Hex
—
—
—
—
—
106 to
—
125
—