YASKAWA V1000 Series Installation & Start-Up Manual page 383

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
Name
Motor Overheat Fault
L1-04
Operation Selection
(PTC input)
Motor Temperature
L1-05
Input Filter Time
(PTC input)
Continuous
L1-13
Electrothermal
Operation Selection
Use L2 parameters to configure drive functions for momentary power loss conditions.
Momentary Power
L2-01
Loss Operation
Selection
Momentary Power
L2-02
Loss Ride-Thru Time
Momentary Power
L2-03
Loss Minimum
Baseblock Time
Momentary Power
L2-04
Loss Voltage
Recovery Ramp Time
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
Sets stopping method when the motor
temperature analog input
(H3-02 or H3-10 = E) exceeds the OH4 fault
level (2.34V).
0: Ramp to Stop
1: Coast to Stop
2: Fast-stop
This parameter adjusts the filter on the motor
temperature analog input
(H3-02 or H3-10 = E). Increase to add stability,
decrease to improve response.
Determines whether or not to hold the
electrothermal value when the power supply is
interrupted.
0: Disabled
1: Enabled
L2: Momentary Power Loss
Enables and disables the momentary power
loss function.
0: Disabled - Drive trips on (UV1) fault when
power is lost.
1: Power Loss Ride-Thru Time - Drive will
restart if power returns within the time set in
L2-02.
2: CPU Power Active - Drive will restart if
power returns prior to control power supply
shut down.
Sets the Power Loss Ride-Thru time. This
value is dependent on the drive capacity. Only
effective when L2-01 = 1.
Sets the minimum wait time for residual motor
voltage decay before the drive output
reenergizes after power loss ride-thru. After a
power loss, if L2-03 is greater than L2-02,
operation resumes after the time set in L2-03.
Sets the time for the output voltage to return to
the preset V/f pattern after speed search
(current detection mode) is complete.
B.2 Parameter Table
Control
Mode
Range Def.
Addr.
O
V/
P
Hex
L
f
M
V
0 to 2
1
A A A 483
0.00 to
0.20
A A A 484
10.00
s
0 to 1
1
A A A 46D
0 to 2
0
A A A 485
For a restart to occur, the run
command must be maintained
throughout the ride-thru
period.
0.0 to
A A A 486
<12>
25.5
0.1 to
A A A 487
<12>
5.0
0.0 to
A A A 488
<12>
5.0
Pg.
B
383

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents