4.5 Test Run
Motor Data for Auto-Tuning
Summary of parameters normally set during Auto-Tuning.
No.
Name
Selects which set of motor parameters are set during
Motor
Auto-Tuning. If Motor 2 selection (H1-
T1-00
Selection
selected, this parameter will not be displayed.
1/2
1: Motor 1 - E1 to E2
2: Motor 2 - E3 to E4
Selects the Auto-Tuning mode.
0: OLV Rotational Auto-Tuning (A1-02 = 2)
2: Terminal resistance only, Stationary Auto-Tuning
Auto-
(A1-02 = 0, 2)
Tuning
T1-01
3: V/f Rotational Auto-Tuning
Mode
(A1-02 = 0) Only settings 2 and 3 are available when
Selection
using V/f Control. Only setting 2 is available when
using motor 2.
Settings 0 and 2 are available when using OLV Control.
Input the motor nameplate power rating in kW.
HP can be converted to kW using the following:
Motor
HP x .746 = kW
T1-02
Rated
For best performance when using OLV select the drive
Power
so that the motor represents 50 to 100% of the drive
rated power.
Set the motor base voltage according to the information
Motor
T1-03
printed on the motor nameplate.
Rated
Use the voltage associated with the base frequency of
<2>
Voltage
the motor.
Enter the motor-rated current.
For best performance when using OLV select the drive
Motor
so that the motor represents 50 to 100% of the drive
T1-04
Rated
rated current.
Current
Enter the current required at base speed for motors with
extended speed ranges.
Enter the motor base frequency as specified on the
Motor
T1-05
motor nameplate.
Base
Enter the motor base frequency for extended speed
<2>
Frequency
range motors.
Number
Enter the number of motor poles as indicated on the
T1-06
of Motor
motor nameplate.
Poles
168
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
= 16) is not
<1>
Control
Mode
Range
Def.
O
V
L
F
V
A A −
1, 2
1
0
("2" in
A A −
0, 2, 3
V/f
mode)
0.00 to
0.40
A A −
650.00
kW
0.0 to
200.0
A A −
255.5
V
10 to
200% of
A A −
drive
<3>
rated
current
0.0 to
60.0
A A −
400.0
Hz
A A −
2 to 48
4
Addr.
Pg.
P
Hex
M
700
407
701
407
702
407
703
407
704
407
705
407
706
407

Hide quick links: