Main Circuit Wiring; Main Circuit Terminal Functions - YASKAWA V1000 Series Installation & Start-Up Manual

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

3.6 Main Circuit Wiring

3.6
Main Circuit Wiring
This section describes the functions, specifications, and procedures required to
safely and properly wire the main circuit of the drive.
NOTICE: Do not solder the ends of wire connections to the drive. Soldered wiring connections
can loosen over time. Improper wiring practices could result in drive malfunction due to loose
terminal connections.

Main Circuit Terminal Functions

Terminal
R/L1
Main circuit power
S/L2
supply input
T/L3
U/T1
V/T2
Drive output
W/T3
B1
Braking resistor
B2
+1
DC reactor
connection
+2
+1
DC power supply
input
Ground
(2 terminals)
68
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Table 3.1 Main Circuit Terminal Functions
Type
Connects line power to the drive.
Drives with single phase 200 V input power use terminals R/L1
and S/L2 only (T/L3 must not be used).
Connects to the motor.
Available for connecting a braking resistor or the braking resistor
unit option.
These terminals are shorted at shipment. Remove the shorting bar
to install a DC choke.
For connecting a DC power supply.
Note: DC power supply input terminals (+1, –) are both UL and
EU certified.
Grounding Terminal
For 200 V class: 100 Ω or less
For 400 V class: 10 Ω or less
Function
Reference
73
71
91
74
297
59
72

Hide quick links: