Cause
Attempted to use a function in the V/f motor control
method that is only possible in Open Loop Vector Control.
Simple V/f with PG was enabled while not in V/f Control
(H6-01 = 3).
In Open Loop Vector Control, n2-02 is greater than n2-03
In Open Loop Vector Control, C4-02 is greater than C4-06
In PM Open Loop Vector Control, parameters E5-02 to
E5-07 are set to 0.
The following conditions are true in PM Open Loop
Vector Control:
E5-03 does not equal 0
E5-09 are both E5-24 equal to 0, or neither equals 0
Note: Other errors are given precedence over OPE08 when multiple errors occur at the same time.
LED Operator Display
Cause
The following contradictory settings have been made at
the same time:
b5-15 does not equal 0.0 (PID Sleep Function Operation
Level)
The stopping method is set to either DC injection braking
or coast to stop with a timer (b1-03 = 2 or 3).
LED Operator Display
Cause
LED Operator Display
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
oPE09
oPE10
oPE11
5.7 Operator Programming Errors
Possible Solutions
Check the motor control method and the functions
available.
To use Simple V/f with PG, ensure the motor control
method has been set to V/f Control (A1-02 = "0").
Correct parameter settings so that n2-02 is less than
n2-03.
Correct parameter settings so that C4-02 is less than
C4-06.
• Set the correct motor code in accordance with the motor
being used (E5-01).
• When using a special-purpose motor, set E5-
accordance with the Test Report provided.
Set either E5-09 or E5-24 to the correct value, then set
the other to "0".
Set the motor-rated current for PM to "0" (E5-03).
Error Name
PID Control Selection Fault
PID control function selection is incorrect.
Requires that PID control is enabled (b5-01 = 1 to 4).
Possible Solutions
• Set b5-15 to another value besides 0.
• Set the stopping method to coast to stop or ramp to stop
(b1-03 = "0" or "1").
Error Name
V/f Data Setting Error
The following setting errors have occurred where:
E1-04 is greater than or equal to E1-06 is greater than or
equal to E1-07 is greater than or equal to E1-09.
Or the following setting errors have occurred:
E3-04 is greater than or equal to E3-06 is greater than or
equal to E3-07 is greater than or equal to E3-09.
Possible Solutions
Correct the settings for E1-04, -06, -07 and -09 (or E-04,
-06, -07, -09 for motor 2).
Error Name
Carrier Frequency Setting Error
Correct the setting for the carrier frequency.