4.5 Test Run
Enter Data from the Motor Nameplate
After selecting the type of Auto-Tuning, enter the required data from the motor
nameplate.
Note: These instructions continue from Step 8 in Selecting the Type of Auto-Tuning.
Press
to access the motor output power parameter T1-02.
1.
Press
to view the default setting.
2.
3.
Press
to select the digit to edit.
Press
and enter "0.2."
4.
Enter this value based on the motor nameplate data.
Example: 0.4 kW → 0.2 kW
5.
Press
to save the setting.
6.
The display automatically returns to the screen shown in Step 1.
7.
Repeat Steps 1 through 5 to set the following parameters:T1-03,
Motor Rated Voltage; T1-04, Motor Rated Current; T1-05, Motor
Base Frequency; T1-06, Motor Poles; T1-07, Motor Base Frequency
166
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)