C: Tuning - YASKAWA V1000 Series Installation & Start-Up Manual

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
<2> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for
A1-02 = 0-V/f Control.
<5> Default setting is dependent on parameter b5-20, PID Setpoint Scaling.
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<14> Default setting value is dependent on parameter o2-09, Initialization Spec. Selection.
<22> Parameter can be changed during run.
<32> A coasting motor may require a braking resistor circuit to bring the motor to a stop in the required time.
<33> Increase the setting value in increments of 0.1 when estimating the minimum output frequency for a motor
coasting at high speed while attempting Speed-Estimation Type Speed Search.
<34> Increase this value if an OV overvoltage fault occurs when performing Speed Search at start.

C: Tuning

C parameters control various aspects of how the drive accelerates and decelerates
the motor. This includes S-curve, slip compensation, torque compensation and
carrier frequency.
No.
Name
C1-01
Acceleration Time 1
<22>
C1-02
Deceleration Time 1
<22>
C1-03
Acceleration Time 2
<22>
C1-04
Deceleration Time 2
<22>
Acceleration Time 3
C1-05
(Motor 2 Accel
<22>
Time 1)
Deceleration Time 3
C1-06
(Motor 2 Decel
<22>
Time 1)
Acceleration Time 4
C1-07
(Motor 2 Accel
<22>
Time 2)
344
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
C1: Acceleration and Deceleration Times
Use C1 parameters to configure motor acceleration and deceleration.
Sets the time to accelerate from 0 to
maximum frequency.
Sets the time to decelerate from maximum
frequency to 0.
Sets the time to accelerate from 0 to
maximum frequency when using a
multi-function input.
Sets the time to decelerate from maximum
frequency to 0 when using a multi-function
input.
Refer to C1-03
Refer to C1-04
Refer to C1-03
Control
Mode
Range Def.
O
V/
P
L
f
M
V
0.0 to
6000.0
10.0 s S S S
<6>
0.0 to
6000.0
10.0 s S S S
<6>
0.0 to
6000.0
10.0 s A A A 202
<6>
0.0 to
6000.0
10.0 s A A A 203
<6>
0.0 to
6000.0
10.0 s A A A 204
<6>
0.0 to
6000.0
10.0 s A A A 205
<6>
0.0 to
6000.0
10.0 s A A A 206
<6>
Addr.
Pg.
Hex
200
141
201
141

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents