YASKAWA V1000 Series Installation & Start-Up Manual page 171

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

4.
Ensure the motor is rotating in the correct direction and no faults or
alarms occur.
Press
to increase the frequency reference. Increase the
frequency in 10 Hz increments verifying smooth operation results at
5.
all speeds. For each frequency monitor the drive output current
(U1-03) through the LED operator to confirm the current is well
below the motor rated current.
s
Example: 6 Hz → 50 Hz/60 Hz
Note:
Refer to Auto-Tuning Errors on page 201
errors that occur while Auto-Tuning the drive.
The drive should operate normally.
6.
Press
to stop the motor.
STOP
RUN flashes until the motor comes to a complete stop.
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)