YASKAWA V1000 Series Installation & Start-Up Manual page 364

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
Motor Code
E5-01
Selection (for
<25>
PM motor)
Motor Rated
E5-02
Capacity (for
<25>
PM motor)
Motor Rated
E5-03
Current (for
PM motor)
Motor Poles
E5-04
(for PM
<25>
motor)
Motor
E5-05
Armature
Resistance (for
<25>
PM motor)
364
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
E5: PM Motor Parameters
Enter the Yaskawa motor code for the motor
being used. Various motor parameters are
automatically set based on the value of this
parameter.
Note: Set to FFFF when using a specialized
or custom motor. For all other motors:
0 0 0 0
0: Pico motor
0: 1800 r/min
(SMRA series)
1: Derated torque
1: 3600 r/min
IPM motor
(SSR1 series)
2: 1750 r/min
2: Constant torque
IPM motor
3: 1450 r/min
(SST4 series)
4: 1150 r/min
F: Custom motor
Each time this parameter is set, all motor
parameters are re-initialized to factory
settings. The user should refrain from setting
this parameter more than once.
Sets the rated capacity of the motor.
Sets the motor rated current in amps.
Sets the number of motor poles.
Set the resistance for each motor phase in
units of 0.001 Ω.
Range
Motor voltage
class and
capacity
0000 to
series
FFFF
series
series
series
series
0.40 to
18.5
10 to
200% of
drive
rated
current
<27>
2 to 48
0.000 to
65.000
Control
Mode
Def.
Addr.
O
P
Hex
V/f
L
M
V
<12> <
S
329
38>
S
32A
<10>
S
32B
<4>
S
32C
<10>
S
32D
<10>
Pg.
122
122
122
122
122

Hide quick links: