YASKAWA V1000 Series Installation & Start-Up Manual page 425

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
E2-01
Motor Rated Current
(E4-01)
E2-02
Motor Rated Slip
(E4-02)
E2-03
Motor No-Load Current
(E4-03)
E2-05
Motor Resistance Between Lines
(E4-05)
E2-06
Motor Leakage Inductance
(E4-06)
E2-10
Torque Compensation Motor Loss
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Minimum Baseblock Time
L2-04
Voltage Restoration Time
L3-24
Inertia Motor Acceleration Time
L8-02
OH Pre-Alarm Level
L8-04
OH Detection Level
L8-09
Ground Protection Selection
L2-05
UV Detection Level
Two Phase/Three Phase Switching Voltage
C6-21
Level (%)
Two Phase/Three Phase Switching
C6-22
Frequency Level (Hz)
Three-Phase 400 V Class Models
CIMR-V 4A0009 to CIMR-V 4A0011
Table B.5 Default Settings Determined by Drive Capacity (o2-04):
Three-Phase 400 V Class Models CIMR-V 4A0009 to CIMR-V 4A0011
No.
Drive Capacity
E2-11
Motor Rated Capacity
E4-11
Motor Rated Capacity for Motor 2
o2-04
Drive Capacity Selection
b3-04
V/f during Speed Search
b3-06
Output Current 1 during Speed Search
b8-04
Energy Saving Coefficient
C6-02
Carrier Frequency Selection
Carrier Frequency Selection Upper Limit
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Name
Units
Name
B.2 Parameter Table
Factory Default Value
A
0.6
1
Hz
2.5
2.9
A
0.4
0.6
Ω
83.94
38.198
%
21.9
18.2
W
12
14
sec.
0.1
0.1
sec.
0.2
0.2
sec.
0.3
0.3
sec.
0.151
0.178
°C
100
100
°C
110
110
0
0
C
380
380
%
30
30
Hz
18
18
Units
Factory Default Value
kW
43P0
150 (96H)
%
kHz
kHz
1.6
3.1
4.2
2.6
2.5
3
0.8
1.4
1.5
22.459
10.1
6.495
14.3
18.3
18.7
26
53
77
0.2
0.3
0.5
0.3
0.4
0.5
0.3
0.3
0.3
0.142
0.166
0.145
100
100
100
110
110
110
0
0
0
380
380
380
30
30
30
18
18
18
43P7
151 (97H)
100
0.5
245.8
8
15
425
B

Hide quick links:

Advertisement

Table of Contents