YASKAWA V1000 Series Installation & Start-Up Manual page 411

Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
Name
Output Frequency
U1-16
after Soft Start
U1-18 OPE Fault Parameter
MEMOBUS/Modbus
U1-19
Error Code
U1-24 Input Pulse Monitor
U1-25 Software No. (Flash)
U1-26 Software No. (ROM)
U2-01 Current Fault
U2-02 Previous Fault
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
Displays the output frequency following Soft
Start.
Units are determined by o1-03.
Displays the parameter number for oPE
or Err (operator error) where the error
occurred.
Displays the contents of a MEMOBUS/
Modbus error.
U1-18 = 0 0 0 0 0 0 0 0
1: CRC error
1: Data length
Not used
(normally 0)
1: Parity error
1: Overrun error
1: Framing error
1: Timed out
Not used
(normally 0)
Displays the frequency of the Pulse Train
(RP) input.
Yaskawa Flash ID
Yaskawa ROM ID
U2: Fault Trace
Use U2 monitor parameters to view fault trace data.
Display of the current fault.
Display of the previous fault.
B.2 Parameter Table
Range
10 V: Max
frequency
No output
signal
available
error
No output
signal
available
32000
No signal
output
available
No signal
output
available
No signal
output avail.
No signal
output avail.
Control
Mode
Def.
Addr.
O
V/
P
Hex
L
f
M
V
0.01
A A A
53
Hz
A A A
61
A A A
66
B
7D
4D
5B
A A A
80
A A A
81
411