B.2 Parameter Table
No.
Name
High-Slip Braking
n3-02
Current Limit
High-Slip Braking
n3-03
Dwell Time at Stop
High-Slip Braking
n3-04
Overload Time
Overexcitation
n3-13
Deceleration Gain
High-Slip
n3-21
Suppression Current
Level
Overexcitation
n3-23
Operation Selection
Use n6 parameters to adjust the motor line-to-line resistance while the drive is online.
Line-to-Line Motor
n6-01
Resistance Online
Tuning
398
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
Sets the maximum current draw during an HSB
stop. Higher n3-02 settings will shorten motor
stopping times but cause increased motor
current, and therefore increased motor heating.
Sets the amount of time the drive will Dwell at
E1-09 (Minimum Frequency) at the end of
deceleration.
If this time is set too low, the machine inertia
can cause the motor to rotate slightly after the
HSB stop is complete and the drive output is
de-energized.
Sets the time required for an HSB overload
fault (OL7) to occur when the drive output
frequency does not change during an HSB
stop. This parameter does not typically require
adjustment.
Applies a gain to the V/f pattern during
deceleration. Returns to normal values after
ramp to stop, re-acceleration, and stop
(DB, BB).
To improve the braking power of
overexcitation, increase the gain by 1.25 to
1.30.
When L3-04 = 0, this will improve the ability
of the drive to perform linear deceleration.
If L3-04 = 2, the deceleration time will be
adjusted relative to the speed.
If overcurrent or overload occur during
high-slip deceleration, reduce the high-slip
suppression current level. Set as a percentage
of the drive rated current.
0: Disabled
1: Enabled only when rotating forward
2: Enabled only when in reverse
n6: Online Tuning of Resistance between Motor Lines
Tunes the line-to-line motor resistance online.
0: Disabled
1: Enabled
Control
Mode
Range Def.
O
V/
P
L
f
M
V
100 to
150
A − −
200
%
0.0 to
1.0 s A − − 58A
10.0
30 to
40 s A − − 58B
1200
1.00 to
1.10 A A −
1.40
100
A A −
0 to 150
%
A A −
0 to 2
0
− A −
0,1
1
Addr.
Pg.
Hex
589
531
579
570

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents