4.4 Basic Parameter Adjustments
Setting Instructions for Setting a V/f Pattern
1.
Set the input voltage for the drive.
E1-01 on page
2.
Select one of the two following V/f patterns:
• Select one of the 15 preset V/f patterns (setting = 0 through E)
• Select the Custom V/f pattern (setting = F)
Note: Parameters E1-04 to E1-10 are set automatically and cannot be individually
adjusted when using one of the preset patterns. When using the custom pattern
(E1-03 = F) parameters E1-04 to E1-10 can be manually adjusted to tailor the V/f
pattern to the desired settings.
3.
The parameters listed below are set automatically when using one of the
preset patterns. (E1-03 = 0 to E)
When using a custom V/f pattern, set these parameters as desired:
No.
Parameter Name
E1-04
Maximum Output Frequency (FMAX)
E1-05
Maximum Voltage (VMAX)
E1-06
Base Frequency (FA)
E1-07
Mid Output Frequency (FB)
Figure 4.23
Note: Drive capacity determines the default settings for the E1 parameters.
144
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
129.
E1-08
E1-09
E1-10
Output Voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
Figure 4.23 V/f Pattern
Refer to Drive Input Voltage Setting
No.
Parameter Name
Mid Output Frequency Voltage (VC)
Minimum Output Frequency (FMIN)
Minimum Output Frequency Voltage (VMIN)