B.2 Parameter Table
<1> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for
A1-02 = 2-OLV control.
<2> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for
A1-02 = 0-V/f Control.
<3> Default setting value is dependent on parameters o2-04, Drive/kVA Selection, and A1-02, Control Method
Selection.
<6> Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. When C1-10 = 0 (units of
0.01 seconds), the setting range becomes 0.00 to 600.00 seconds.
<8> Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
<22> Parameter can be changed during run.
<23> Parameter cannot be changed during run when parameter A1-02 = 5-PM OLV Control.

d: References

Reference parameters are used to set the various frequency reference values during
operation.
No.
Name
d1-01
Frequency
Reference 1
<22>
d1-02
Frequency
Reference 2
<22>
d1-03
Frequency
Reference 3
<22>
d1-04
Frequency
Reference 4
<22>
d1-05
Frequency
Reference 5
<22>
d1-06
Frequency
Reference 6
<22>
d1-07
Frequency
Reference 7
<22>
350
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
Frequency reference when multi-function input
"Multi-Step Speed Reference 1" (H1-
on.
Frequency reference when multi-function input
"Multi-Step Speed Reference 2" (H1-
is on.
Frequency reference when multi-function input
"Multi-Step Speed Reference 1, 2"
(H1-
= 3 and 4) is on.
Frequency reference when multi-function input
"Multi-Step Speed Reference 3" (H1-
on.
Frequency reference when multi-function input
"Multi-Step Speed Reference 1, 3 "
(H1-
= 3 and 5) is on.
Frequency reference when multi-function input
"Multi-Step Speed Reference 2, 3"
(H1-
= 4 and 5) is on.
Control
Mode
Range Def.
V/
f
0.00
S S S
Hz
0.00
= 3) is
S S S
Hz
0.00
= 4)
S S S
Hz
0.00 to
400.00
0.00
S S S
Hz
Hz
<11>
<19>
0.00
= 5) is
A A A 284
Hz
0.00
A A A 285
Hz
0.00
A A A 286
Hz
Addr.
Pg.
O
P
Hex
L
M
V
280
177
281
177
282
177
283
177