B.2 Parameter Table
No.
Name
Motor Iron
T1-11
Loss
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<41> If T1-01 = 2, then T1-02 and T1-04 must also be set.

U: Monitors

Monitor parameters allow the user to view drive performance and other
information about drive operation.
No.
Name
U1-01 Frequency Reference
U1-02 Output Frequency
U1-03 Output Current
U1-04 Control Mode
U1-05 Motor Speed
Output Voltage
U1-06
Reference
408
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07)
Description
Provides the iron loss for determining the Energy
Saving coefficient.
When power is cycled, the value set to E2-10 will
appear (the motor iron loss). If T1-02 is changed,
an initial value for the motor capacity will appear
that is close to the capacity that was changed.
Description
U1: Operation Status Monitors
Use U1 monitors to display the operation status of the drive.
Monitors the frequency reference in Remote
mode.
Displays the output voltage. Display units are
determined by o1-03.
Displays the output current.
Control method set in A1-02.
0: V/f without PG
2: Open Loop Vector (OLV)
5: PM Open Loop Vector (PM)
Displays the motor speed feedback.
Display units are determined by o1-03.
Displays the output voltage.
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
14W A − − 70B
These values differ
0 to
depending on the motor
65535
code value and motor
parameter settings.
Control
Mode
Range
Def.
V/
f
10 V: Max
0.01
A A A
frequency
Hz
10 V: Max
0.01
A A A
frequency
Hz
10 V: Drive
0.01
A A A
rated current
A
No output
signal
A A A
available
10 V:
0.01
Maximum
– A A
Hz
speed
10 V: 200
0.1
Vrms
A A A
V
(400 Vrms)
Addr.
Pg.
Hex
Addr.
O
P
Hex
L
M
V
40
41
42
43
44
45