Reliability Systems: A Maintenance Aid
Table 6-2. Software-Requested Interchanges Caused by Alarm Conditions
Maintenance
Object
STBY-SPE
WARNING
MEM-BD
MAJOR or MINOR
MEMORY
MAJOR or MINOR
STBY-SPE
MAJOR
PROCR
MAJOR
SW-CTL
MAJOR
MEM-CARD
MAJOR
DUPINT
MAJOR
CARR-POW
MAJOR
SHDW-CIR
MAJOR
SHDW-LINK
MAJOR
SW-CTL
MINOR
PR-MAINT
MINOR
PI-BD
MAJOR or MINOR
PKT-CTRL
MAJOR
PKT-CTRL
MINOR
PI-PT
MAJOR
DATA-CHL
MINOR
DATA-CON
MINOR
DATA-BD
MINOR
CARD-MEM
MINOR
PR-MAINT
MINOR
1
If the Standby SPE is in Standby mode when the alarm occurs, a Hot SPE-Interchange occurs. If
the Standby is in Maintenance mode when the alarm occurs, however, a Warm SPE-Interchange
rather than a Hot SPE-Interchange occurs.
Regardless of the condition that initiates an SPE-interchange, the G3MT is always
logged off as a result of the SPE-interchange. The G3MT is available to log into
after the SPE-interchange is complete and the "login" prompt is displayed.
6-14
Issue 4 May 2002
On/Off
Alarm Level
Board
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON or OFF
ON
ON
ON
ON
ON or OFF
ON or OFF
ON
ON
ON
ON
ON or OFF
OFF
Fault Severity
Level
Restart Level
120
None
110
Hot or Warm
110
Hot or Warm
100
None
70
Hot or Warm
65
Cold 2
65
Cold 1
61
Hot
61
Cold 2
60
Warm
60
Warm
40
Hot
30
Hot
20
Hot
20
Hot
15
Hot
15
Hot
15
Hot
15
Hot
15
Hot
10
Hot
8
Hot
555-233-123