ABB RELION Series Technical Manual page 668

Grid automation
Hide thumbs Also See for RELION Series:
Table of Contents

Advertisement

Section 9
Control functions
Parameter
Sixth reclose time
Seventh reclose time
Init signals CBB1
Init signals CBB2
Init signals CBB3
Init signals CBB4
Init signals CBB5
Init signals CBB6
Init signals CBB7
Shot number CBB1
Shot number CBB2
Shot number CBB3
Shot number CBB4
Shot number CBB5
Shot number CBB6
Shot number CBB7
Frq Op counter limit
Frq Op counter time
Frq Op recovery time
Auto init
Table 670:
DARREC Non group settings (Advanced)
Parameter
Manual close mode
Wait close time
Max wait time
Max trip time
Max Thm block time
Cut-out time
Dsr time shot 1
Dsr time shot 2
Dsr time shot 3
Dsr time shot 4
Auto wait time
Auto lockout reset
Table continues on next page
662
Values (Range)
Unit
0...300000
ms
0...300000
ms
0...63
0...63
0...63
0...63
0...63
0...63
0...63
0...5
0...5
0...5
0...5
0...5
0...5
0...5
0...250
1...250
min
1...250
min
0...63
Values (Range)
Unit
0=False
1=True
50...10000
ms
100...1800000
ms
100...10000
ms
100...1800000
ms
0...1800000
ms
0...10000
ms
0...10000
ms
0...10000
ms
0...10000
ms
0...60000
ms
0=False
1=True
Step
Default
10
5000
10
5000
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
1
1
0
Step
Default
0=False
50
250
100
10000
100
10000
100
10000
100
10000
100
0
100
0
100
0
100
0
10
2000
1=True
1MRS758755 A
Description
Dead time for CBB6
Dead time for CBB7
Initiation lines for CBB1
Initiation lines for CBB2
Initiation lines for CBB3
Initiation lines for CBB4
Initiation lines for CBB5
Initiation lines for CBB6
Initiation lines for CBB7
Shot number for CBB1
Shot number for CBB2
Shot number for CBB3
Shot number for CBB4
Shot number for CBB5
Shot number for CBB6
Shot number for CBB7
Frequent operation counter lockout limit
Frequent operation counter time
Frequent operation counter recovery time
Defines INIT lines that are activated at
auto initiation
Description
Manual close mode
Allowed CB closing time after reclose
command
Maximum wait time for BLK_RECL_T
release
Maximum wait time for deactivation of
protection signals
Maximum wait time for thermal blocking
signal deactivation
Cutout time for protection coordination
Discrimination time for first reclosing
Discrimination time for second reclosing
Discrimination time for third reclosing
Discrimination time for fourth reclosing
Wait time for reclosing condition fullfilling
Automatic lockout reset
REC615 and RER615