Functionality

The set-reset (8 pcs) function SRGAPC is a simple SR flip-flop with a memory that
can be set or that can reset an output from the S# or R# inputs, respectively. The
function contains eight independent set-reset flip-flop latches where the SET input has
the higher priority over the RESET input. The status of each Q# output is retained in
the nonvolatile memory. The individual reset for each Q# output is available on the
LHMI or through tool via communication.
Table 151:
Truth table for SRGAPC
S#
0
0
1
1
1) Keep state/no change

Signals

Table 152:
SRGAPC Input signals
Name
Type
S1
BOOLEAN
R1
BOOLEAN
S2
BOOLEAN
R2
BOOLEAN
S3
BOOLEAN
R3
BOOLEAN
S4
BOOLEAN
R4
BOOLEAN
S5
BOOLEAN
R5
BOOLEAN
S6
BOOLEAN
R6
BOOLEAN
S7
BOOLEAN
R7
BOOLEAN
S8
BOOLEAN
R8
BOOLEAN
R#
0
1
0
1
Default
Description
0=False
Set Q1 output when set
0=False
Resets Q1 output when set
0=False
Set Q2 output when set
0=False
Resets Q2 output when set
0=False
Set Q3 output when set
0=False
Resets Q3 output when set
0=False
Set Q4 output when set
0=False
Resets Q4 output when set
0=False
Set Q5 output when set
0=False
Resets Q5 output when set
0=False
Set Q6 output when set
0=False
Resets Q6 output when set
0=False
Set Q7 output when set
0=False
Resets Q7 output when set
0=False
Set Q8 output when set
0=False
Resets Q8 output when set