Settings | Axes
Parameters
Spindle position

20.6.24 Adding Gear stages

Settings ► Axes ► S► Gear stages ► +
Path:
Parameter

20.6.25 Configuring Gear stages

Settings ► Axes ► S► Gear stages
Path:
Parameter
Name
Gear stage is active
Smax
Start-up time for upper spindle
speed range
Start-up time for lower spindle
speed range
Break point of characteristic
curve for start-up times
Minimum spindle speed
Remove
HEIDENHAIN | POSITIP 8000 | Operating Instructions | 09/2018
Explanation
Assignment of a digital input; the signal positions the spindle at
low speed during stopping to a desired position
Default value: Not connected
Explanation
Adding a new gear stage with default name
Further information:
"Configuring Gear stages", Page 345
Explanation
Entry of the name for the gear stage
Default value: Stage [n]
Assignment of the digital input for selection of the gear stage via
an external signal
Default value: Not connected
Definition of the Spindle speed attained with Umax
Setting range: 100 rpm ... 10 000 rpm
Default value: 2000
Definition of the required Start-up time until Smax is reached
Setting range: 50 ms ... 10 000 ms
Default value: 500
Definition of the required Start-up time until Smax is reached
Setting range: 50 ms ... 10 000 ms
Default value: 500
Setting of the spindle speed that marks the transition from the
upper to the lower spindle speed range
Setting range: 0 rpm ... 2000 rpm
Default value: 1500
Definition of the minimum spindle speed
Setting range: 0 rpm ... 500 rpm
Default value: 50
Removal of the selected gear stage