20
Parameter
Reference system
Axis
Switching point
Type of switching
Output
Pulse
Pulse time
Lower limit
Upper limit
Remove the entry
318
Explanation
Selecting the desired reference system
Machine coordinate system
Preset
Target position
Tool tip
Selecting the desired axis
X
Y
Z
Zo
Selecting the axis position of the trigger point
Default setting: 0.0000
Selecting the desired type of switching
Edge from LOW to HIGH
Edge from HIGH to LOW
Interval from LOW to HIGH
Interval from HIGH to LOW
Default setting: Edge from LOW to HIGH
Selecting the desired output
X105.13 ... X105.16 (Dout 0, Dout 2, Dout 4, Dout 6)
X105.32 ... X105.35 (Dout 1, Dout 3, Dout 5, Dout 7)
X113.04 (Dout 0)
Selecting whether the pulse should be activated or deactivated
Settings: ON or OFF
Default setting: ON
Selecting the desired pulse length
0.1 s ... 999 s
Default setting: 0.0 s
Selecting the lower limit of the axis position at which switching
is to occur (only with Interval type of switching)
Selecting the upper limit of the axis position at which switching
is to occur (only Interval type of switching)
Removing the position-dependent switching function
HEIDENHAIN | POSITIP 8000 | Operating Instructions | 09/2018