HEIDENHAIN POSITIP 8000 Operating Instructions Manual page 332

Hide thumbs Also See for POSITIP 8000:
Table of Contents

Advertisement

20
Parameters
Kv factor P
Kv factor L
Maximum positioning error
Maximum standstill error
Positioning window
332
Explanation
Proportional component of the position controller during
positioning
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
Proportional component of the position controller at a standstill
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
Definition of the maximum following error during positioning
Setting range: 5 µm ... 1000 µm
Default value: 500
Definition of the maximum position deviation at a standstill
Setting range: 5 µm ... 1000 µm
Default value: 100
Input of the scaling factor for the positioning aid in MDI mode
(only for manually operated linear axes)
Setting range: 0.020 mm ... 2.000 mm
Default value: 0.100
HEIDENHAIN | POSITIP 8000 | Operating Instructions | 09/2018
Settings | Axes