20

20.6.19 Inputs

Path:
Parameters
Enable digital movement
commands
Input for digital movement
command in positive direction
Input for digital movement
command in negative direction
Movement commands from
analog input
Input for analog movement
commands
Umax
Fmax
Digital enable inputs
Input for error signal
Signal is low-active
340
Settings ► Axes ► X, Y ... ► Inputs
Explanation
Use of the digital movement commands for the spindle
Settings: ON or OFF
Default value: OFF
Assignment of the digital input for the movement command in
the positive direction according to pin layout
Default value: Not connected
Assignment of the digital input for the movement command in
the negative direction according to pin layout
Default value: Not connected
Configuration of the movement commands of external input
devices (such as a joystick) via the analog input
Assignment of the analog input for the movement commands
according to pin layout
Default value: Not connected
Maximum voltage at the analog input in order to achieve Fmax
Setting range: 1000 mV ... 5000 mV
Default value: 5000
Definition of the feed rate achieved at Umax
Setting range: 100 mm/min ... 2000 mm/min
Default value: 2000
Configuration of the digital inputs for the enable
Assignment of the digital input for the enable signal of the servo
amplifier according to pin layout
Default value: Not connected
If the function is active, the axis is enabled when the signal is
low at the input