HEIDENHAIN POSITIP 8000 Operating Instructions Manual page 172

Hide thumbs Also See for POSITIP 8000:
Table of Contents

Advertisement

8
Manual presetting
If you create presets manually in the preset table, the following applies:
The entry in the preset table assigns the new position values to the current
actual position of the individual axes
Clearing the entry with CE resets the position values for the individual axes
to the machine zero point again. The new position values are thus always
referenced to the machine zero point
172
Tap Presets on the status bar
The Presets dialog appears
Tap Open table
The Preset table dialog appears
Tap Add
Enter a name in the Description input field
Tap the input field for one or more desired axes and enter the
appropriate position value
Confirm the entry with RET
The defined preset is added to the preset table
To protect the entry for a preset from accidental changes or
deletion, tap the Lock symbol next to the preset's entry
The symbol changes and the entry is locked
Tap Close
The Preset table dialog is closed
Setup | Single steps for setup
HEIDENHAIN | POSITIP 8000 | Operating Instructions | 09/2018