Protection Function - Canon imagePRESS C1 P Service Manual

Imagepress c1 series
Table of Contents

Advertisement

Chapter 10
Operation mode
Main power switch
All-night
3.3VR
Non-all-night
13VA
13VB
13V4A
24V1x
24V2x
24V3x (DC relay)
24V4x
AC relay
Sub power supply
(24V)
Optional power
supply (24V) *1
*1: When the DADF is mounted.
*2: The same can be said at the time of standby, warm-up, and recovery.

10.4.2 Protection Function

10.4.2.1 Protective Functions
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
The machine's DC power supply PCB and those of its accessories are equipped with protective functions against excess current and voltage, which will automati-
cally cut off the output voltage in response to an error power condition (caused, for example, by a short-circuit on a load).
If any of these protective mechanism has gone on, turn off the main power switch of the printer unit, and remove the cause of activation; then, leave the machine
alone for about 3 min, and turn its power back on to reset it.
10.4.3 Backup Battery
10.4.3.1 Backup Battery
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
The SRAM PCB and the DC controller PCB of the machine's main controller PCB are equipped with a lithium battery (1 pc. each) serving as a backup source of
power in the event of a power shortage or when the power plug is removed.
SRAM PCB
DC controller PCB
Life
Replacement
LISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Do not use a battery which is not of a type specifically indicated (same name, or equivalent).
Dispose of any used battery according to the instructions of its manufacturer.
10.4.4 Energy-Saving Function
10.4.4.1 Overview
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
1. Standby Mode
The machine is in operation or is ready to start operation, with all its loads supplied with power.
2. Power Save Mode
The machine deceases the control temperature while the fixing assembly is in a standby state according to the selected power save rating (variable through 'change
power save mode' in user mode; default: -10%), thus decreasing the power consumption.
Conditions Initiating a Shift from Standby Mode (standby -> power save)
10-8
Main power SW
OFF
Deep sleep
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
manganese dioxide lithium battery (3 V, 100 mAh)
lithium battery (3 V, 6000 mAh)
10 yr or more (true of both; with power plug removed)
not possible in the field on its own.
T-10-5
Low power (&
Shallow sleep
power saving)
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
T-10-6
Door open
Fixing error
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
Print (*2)
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
0014-1316
0014-1317
0014-1318

Hide quick links: