Canon imagePRESS C1 P Service Manual page 944

Imagepress c1 series
Table of Contents

Advertisement

Subheading
SGNL-A-K
Latest patch result in each pattern of ARCDAT (K in Screen A)
Setting range: 0 to 1023
Standard value: 0
SGNL-B-Y
Latest patch result in each pattern of ARCDAT (Y in Screen B)
Setting range: 0 to 1023
Standard value: 0
SGNL-B-M
Latest patch result in each pattern of ARCDAT (M in Screen B)
Setting range: 0 to 1023
Standard value: 0
SGNL-B-C
Latest patch result in each pattern of ARCDAT (C in Screen B)
Setting range: 0 to 1023
Standard value: 0
SGNL-B-K
Latest patch result in each pattern of ARCDAT (K in Screen B)
Setting range: 0 to 1023
Standard value: 0
SGNL-C-Y
Latest patch result in each pattern of ARCDAT (Y in Screen C)
Setting range: 0 to 1023
Standard value: 0
SGNL-C-M
Latest patch result in each pattern of ARCDAT (M in Screen C)
Setting range: 0 to 1023
Standard value: 0
SGNL-C-K
Latest patch result in each pattern of ARCDAT (K in Screen C)
Setting range: 0 to 1023
Standard value: 0
SGNL-C-C
Latest patch result in each pattern of ARCDAT (C in Screen C)
Setting range: 0 to 1023
Standard value: 0
DLTA-A-Y
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
DLTA-A-M
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
DLTA-A-C
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
DLTA-A-K
Difference between the latest patch result and the target value in each pattern of ARCDAT (K in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
DLTA-B-Y
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
DLTA-B-M
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
DLTA-B-C
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
DLTA-B-K
Difference between the latest patch result and the target value in each pattern of ARCDAT (K in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
DLTA-C-Y
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
DLTA-C-M
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
DLTA-C-C
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
COPIER > DISPLAY > HT-C
Contents
Chapter 16
Level
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
16-47