Canon imagePRESS C1 P Service Manual page 1059

Imagepress c1 series
Table of Contents

Advertisement

Chapter 16
Subheading
W-CLN-P
W-CLN-T
PRI-FAN
SCANSLCT
DH-SW
SENS-CNF
16-162
COPIER>OPTION>BODY
Set the interval (number of copies) to perform automatic cleaning of the primary charging wire in
the normal environment.
The setting value becomes valid after the main power switch is turned OFF/ON.
Setting range
50 to 10000 (copies)
Standard value
2000
Set the interval (number of copies) to perform automatic cleaning of the charging wire of the pre-
transfer charging assembly.
Setting range
50 to 10000 (copies)
Select the primary fan drive mode.
Prevent the half tone unevenness due to the soiled primary charging assembly grid.
Setting range
0: Half speed in the high temperature/humidity environment
1: Full speed mainly in the low temperature / low humidity environment.
Standard value
0
The setting value becomes valid after the main power switch is turned OFF/ON.
Set ON/OFF of the function to calculate the scan area based on the paper size.
Setting range
0: OFF (Determine the scan area by document detection.)
1: ON (Determine the scan area by paper size.)
Standard value
0
When setting as '1', if the media size is larger than the original size, productivity decreases due to
a larger scanning area.
Perform Dhalf correction.
Setting range
0: Do not perform Dhalf control.
1: Perform Dhalf control.
Standard value
1
The setting value becomes valid after the main power switch is turned OFF/ON.
Set the display of the document detection sensor.
Setting range
0: AB system
1: Inch system
Standard value
0
Due to the reader controller PCB RAM clear, the value is set as '0'. Re-define the value as '1' for
inch-configuration destination machines (North America etc.,)